In the spirit of information sharing, here’s a little oddity that came our way via our Chinese distribution network. Just in case anyone sees this behaviour on their DP446, you’ll know it’s been fixed!
The scenario is thus:
1) Set up a configuration, routing etc…crossover, EQ, all the usual. During the “Design a crossover” process, when asked if you wanted to clear the output filters, you said “Yes”.
2) Store this as “Everything”.
3) A subsequent recall of this as “Everything” (so not “Xover only” settings) doesn’t work, and you get default settings recalled (the correct settings have been stored – it’s a recall bug) and then the outputs mute.
There is a workaround if you have experienced this – just recall only the Crossover settings out fo the memory location, not “Everything”. Subsequent recalls will also then be fine.
Alternately, just download the new firmware from the website. Remember – this is specific to the DP446 – no other 4 Series units are affected.
hello
i want firmware dp448 version 2.10
thx
Hi there – the latest release of firmware for your 448 is here:
https://audiocore.wpengine.com/wp-content/uploads/2016/05/upgrdxta.zip
Version 2.10 was never a general release version – unless you’ve a very specific need for updating using older firmware I would not recommend it.
If you need any further help, please email waring@xta.co.uk to make sure you get a timely reply, as the comments on here sometimes get missed!
Thanks and best regards,
Waring